ELECTRICAL

For over 70 years, Malloy has provided electrical solutions to our customers. Malloy works with the customer to supply anything from advanced motor control to simple replacement components. Our staff is exceedingly qualified to deal with all aspects of the Electrical Industry ranging from utility transformers, switchboards, MCCs, soft starts and VFDs – all the way down to the smallest pushbutton or relay in your facility. Malloy is fully outfitted to deal with low or high voltage equipment (24V to 4160V), new services, or parts from an existing product.


Malloy provides many services including:

Helping the customer size and select the best starting method for their specific application.
Providing technical documentation including dimensions/drawings, component ratings, industry approvals, etc.
Custom configuring complete motor control solutions.
Upgrading damaged or obsolete components with high quality replacements.
Working directly with the manufacturers to ensure that product performance matches customer expectations.
We are committed to providing high quality manufactured products to meet all electrical needs!

Services

  • Circuit Breaker Testing

    Circuit breakers are the first line of defense in case something goes wrong with a system. They are designed to work reliably for years. Without routine maintenance and testing, you cannot be sure that the circuit breakers will function reliably. We use state of the art digitally controlled current injection testing to check circuit breakers on site. Malloy can test air drawout, insulated or molded breakers ranging from 15-4,000 amps. A malfunctioning breaker that does not open during an overload or short circuit condition can cause considerable loss of electrical and mechanical assets as well as potentially destructive fires.

    Using Breaker Testing helps make sure that the breakers are protecting business investments properly!

    Electrical Preventative Maintenance Testing does not end with circuit breaker testing……

    • A great deal can go wrong if an electrical distribution system is not adequately maintained.

    • As electrical loads cycle between high and low demand, thermal expansion and contraction cause connections to loosen.

    • Electrical panels that are never cleaned accumulate dust and dirt that deposits on these connections.

    • The loose and dirty connections provide a high resistance path that is directly responsible for more than 30 percent of electrical failures.

    • Another 17 percent of electrical failures are attributed to live electrical components being exposed to moisture.

    With a comprehensive electrical preventative maintenance program, both of the above conditions – which account for almost half of all electrical losses, can be corrected

    • According to the Institute of Electrical and Electronics Engineers (IEEE), the failure rate of electrical components is three times (3X) higher for systems where preventative maintenance is not performed.

    • This tells us that electrical failures, for the most part, can be avoided.

    The type of tests and frequency of tests are detailed in the NFPA-70B documentation – please call for a copy.

    Malloy offers and recommends Electrical Preventative Maintenance Testing for the following items:

    • Switchgear Testing

    • Motor Control Centers (LV & MV)

    • Circuit Breaker (LV & MV), Primary &Secondary Injection Testing

    • Protective Relay Testing

    • Transformer Testing – TTR, Megger

    • Transformer – Dissolved Gas Analysis & Fluid Analysis plus Sample Safe Installation

    • Ground Grid Testing

    • MV Starter Testing (air & vacuum types)

    • LV & MV Disconnect Switch Testing

    • Infra-red Thermography

    • LV Breaker Retrofit with solid state trip units

  • Infrared Thermography may save you thousands of dollars by using state of the art Infrared Thermography and Analysis Methods. Variations in temperature can show – among many other things – if an electrical connection is loose or corroded and if a transformer has blocked cooling fins. It can also discover missing refractory brick and insulation in thermal oxidation chambers, kilns and dryers. Infrared Thermography is a non-contact testing method that allows the customer to continue running while determining if there is a “heat related” problem.

    Malloy’s Technical Services Department has certified technicians that understand emissivity, heat reflection readings and “false high temp” findings. Once discovered and eliminated, the customer will be allowed to concentrate on the real problems at hand! Infrared Thermography is recognized by the National Fire Protection Association (NFPA) as a necessary preventative maintenance for your electrical distribution systems. Regular infrared inspections help prevent electrical fires and catastrophic failures that endanger people, productivity, materials and machines.

    Problems can be identified in different types of equipment such as:

    • Bearings

    • Breakers

    • Bus/Wire Connections

    • Fuse Holders

    • Motors

    • Switchgear

    • Transformers

    By identifying and correcting these issues, we will save you money and increase reliability!

  • Sometimes the needs of a customer are too unique to fit the mold of a manufacturer’s standard offering. When this happens, Malloy’s UL508A Panel Shop will custom-configure a complete control package to fit your needs.

    Malloy is recognized as a certified 508A panel shop by Underwriters Laboratories (UL). Following this industry proven standard for industrial control panel building, we can list your control panel for UL and cUL.

    By working closely with the customer and user, Malloy ensures that all of the specific power and control needs are met. Whether it is a single starter panel or a complete multi-panel drive system – Malloy has the capability of handling any and all projects, big and small.